Screening Ventilation Strategies for Confined-Space Manure Storage Facilities

Journal of Agricultural Safety and Health
  • Murphy, Dennis J.;
  • Manbeck, Harvey B.;
  • Pesce, Eric P.;
  • Zhao, Juan

Abstract

Fatalities associated with entry into on-farm confined-space manure storage facilities occur each year. The fatalities are due to asphyxiation or poisoning by exposure to high concentrations of hydrogen sulfide, methane, and carbon dioxide. Forced ventilation has been shown to be an effective way to reduce concentrations of noxious gases to levels that are safe for human entry into these storage facilities. Hydrogen sulfide (H2S) was used as an indicator gas to investigate the effectiveness of forced-air ventilation strategies for eliminating the toxic and oxygen-deficient atmosphere in confined-space manure storage facilities. This article focuses on experimental methods for identifying ventilation strategies that effectively reduce toxic gas (i.e., H2S) concentrations in a fan-ventilated confined-space manure tank to the OSHA permissible exposure limit (PEL) (H2S PEL = 10 ppm) and to 25% of the initial gas concentration. Typical H2S concentration reduction curves during forced-air ventilation were identified in the tank as well. Based on the experimental tests conducted in this research, the most promising candidate ventilation strategies were identified for this rectangular confined-space manure tank with solid, fully slotted, and partially slotted covers. In addition, based on the results of experimental tests, a field-based database was developed for future validation of computational fluid dynamics modeling protocols.

Full article can be found in: Journal of Agricultural Safety and Health
Access this publication at: ASABE Technical Library


Disclaimer and Reproduction Information: Information in NASD does not represent NIOSH policy. Information included in NASD appears by permission of the author and/or copyright holder. More

BACK TO TOP